Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
AJR Am J Roentgenol ; 217(5): 1206-1216, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1559710

ABSTRACT

BACKGROUND. COVID-19 vaccination may trigger reactive lymphadenopathy, confounding imaging interpretation. There has been limited systematic analysis of PET findings after COVID-19 vaccination. OBJECTIVE. The purpose of this study was to evaluate the frequency and characteristics of abnormal FDG and 11C-choline uptake on PET performed after COVID-19 vaccination. METHODS. This retrospective study included 67 patients (43 men and 24 women; mean [± SD] age, 75.6 ± 9.2 years) who underwent PET examination between December 14, 2020, and March 10, 2021, after COVID-19 vaccination and who had undergone prevaccination PET examination without visible axillary node uptake. A total of 52 patients received the BNT162b2 mRNA COVID-19 vaccine (Pfizer-BioNTech; hereafter referred to as the Pfizer-BioNTech vaccine), and 15 received the SARS-CoV-2 mRNA-1273 vaccine (Moderna; hereafter referred to as the Moderna vaccine). Sixty-six of the patients underwent PET/CT, and one underwent PET/MRI. Fifty-four PET examinations used FDG, and 13 used 11C-choline. PET was performed a median of 13 and 10 days after vaccination for patients who had received one (n = 44) and two (n = 23) vaccine doses, respectively. Two nuclear medicine physicians independently reviewed images and were blinded to injection laterality and the number of days since vaccination. Lymph node or deltoid SUVmax greater than the blood pool SUVmax was considered positive. Interreader agreement was assessed, and the measurements made by the more experienced physician were used for subsequent analysis. RESULTS. Positive axillary lymph node uptake was observed in 10.4% (7/67) of patients (7.4% [4/54] of FDG examinations and 23.1% [3/13] of 11C-choline examinations); of the patients with positive axillary lymph nodes, four had received the Pfizer vaccine, and three had received the Moderna vaccine. Injection laterality was documented for five of seven patients with positive axillary lymph nodes and was ipsilateral to the positive node in all five patients. PET was performed within 24 days of vaccination for all patients with a positive node. One patient showed extraaxillary lymph node uptake (ipsilateral supraclavicular uptake on FDG PET). Ipsilateral deltoid uptake was present in 14.5% (8/55) of patients with documented injection laterality, including 42.9% (3/7) of patients with positive axillary lymph nodes. Interreader agreement for SUV measurements (expressed as intraclass correlation coefficients) ranged from 0.600 to 0.988. CONCLUSION. Increased axillary lymph node or ipsilateral deltoid uptake is occasionally observed on FDG or 11C-choline PET performed after COVID-19 vaccination with the Pfizer-BioNTech or Moderna vaccine. CLINICAL IMPACT. Interpreting physicians should recognize characteristics of abnormal uptake on PET after COVID-19 vaccination to guide optimal follow-up management and reduce unnecessary biopsies.


Subject(s)
COVID-19 Vaccines/adverse effects , COVID-19/prevention & control , Deltoid Muscle/diagnostic imaging , Lymphadenopathy/diagnostic imaging , Lymphadenopathy/etiology , Magnetic Resonance Imaging , Positron Emission Tomography Computed Tomography , 2019-nCoV Vaccine mRNA-1273 , Aged , Axilla/diagnostic imaging , BNT162 Vaccine , Carbon Radioisotopes/pharmacokinetics , Choline/pharmacokinetics , Female , Fluorodeoxyglucose F18/pharmacokinetics , Humans , Male , Radiopharmaceuticals/pharmacokinetics , Retrospective Studies , SARS-CoV-2
2.
PLoS One ; 16(1): e0245019, 2021.
Article in English | MEDLINE | ID: covidwho-1079325

ABSTRACT

The knowledge on the deposition and retention of the viral particle of SARS-CoV-2 in the respiratory tract during the very initial intake from the ambient air is of prime importance to understand the infectious process and COVID-19 initial symptoms. We propose to use a modified version of a widely tested lung deposition model developed by the ICRP, in the context of the ICRP Publication 66, that provides deposition patterns of microparticles in different lung compartments. In the model, we mimicked the "environmental decay" of the virus, determined by controlled experiments related to normal speeches, by the radionuclide 11C that presents comparable decay rates. Our results confirm clinical observations on the high virus retentions observed in the extrathoracic region and the lesser fraction on the alveolar section (in the order of 5), which may shed light on physiopathology of clinical events as well on the minimal inoculum required to establish infection.


Subject(s)
COVID-19/virology , SARS-CoV-2/physiology , Aerosols/analysis , COVID-19/metabolism , Carbon Radioisotopes , Humans , Lung/metabolism , Lung/pathology , Lung/virology , Models, Biological , Respiratory System/metabolism , Respiratory System/virology
SELECTION OF CITATIONS
SEARCH DETAIL